Product Description:
Double pole panel mount magnetic circuit breaker with CLASS A tripping characteristics with manual trip combining circuit breaker protection with switching functionality. Suitable for circuits for DC circuits up to 32Vdc.
- Color actuator indicates “OFF” position
- “Trip Free” design cannot be held “ON” during fault current condition
- International ON/OFF symbols support vertical or horizontal mounting
| Amperage |
|
15 A |
| Number of Poles |
|
2 |
| Operating Voltage max |
|
240 VAC, 32 VDC |
| Circuit Breaker Type |
|
Magnetic Hydraulic - trip free |
| Action |
|
Manual Reset / Disconnect |
| Interrupt Capacity ** |
|
3000A @ 240V AC |
| |
|
1500A @ 240V AC [TUV] |
| |
|
5000A @ 32V DC |
| Operating Temperature |
|
-40° C to +85° C |
| Terminal Screws |
|
#10-32 Stainless Steel |
| Terminal Screw Torque |
|
1.58 Nm |
| Mounting Screw |
|
6-32 Stainless Steel |
| Mounting Screw Torque |
|
0.68 Nm |
| Switching Cycles |
|
10000 |
| Weight |
|
0.17 kg |
| Manufacturer |
|
Blue Sea |
| Manufacturer Part Number |
|
7411 |
** The fault current that a device, normally a fuse or circuit breaker is capable of breaking without damage.