| Type |
|
Finder 30.22.7.012.0010 |
| Contact configuration |
|
2 Change Over (DPDT) |
| Rated current / Maximum peak current |
|
2 / 3A |
| Rated voltage / Maximum switching voltage |
|
125 / 250VAC |
| Rated load AC1 |
|
125VA |
| Rated load AC15 (230V AC) |
|
25VA |
| Single-phase motor rating (230VAC) |
|
------- |
| Breaking capacity DC1: 24 / 110 / 220V |
|
2 / 0.3 / ---A |
| Minimum switching load |
|
10 (0.1/10)mW (V/mA) |
| Standard contact material |
|
AgNi + Au |
| Coil specification |
|
|
| Nominal voltage (DC Sensitive) |
|
12VDC |
| Coil Resistance |
|
720 Ohm |
| Rated power |
|
0.2W |
| Operating range |
|
8.4 to 18VDC |
| Holding voltage |
|
4.2VDC |
| Must drop-out voltage |
|
0.6VDC |
| Technical data |
|
|
| Mechanical life DC (cycles) |
|
2 x 10^6 |
| Electrical life at rated load AC1 (cycles) |
|
100 x 10^3 |
| Operate / release time |
|
6 / 4ms |
| Insulation between coil and contacts (1.2/50 μs) |
|
1.5kV |
| Dielectric strength between open contacts |
|
750VAC |
| Ambient temperature range |
|
–40 to +85°C |
| Environmental protection |
|
RT III |
| Dimensions (L x H x W) |
|
20.3 x 11.4 x 10.1mm |
| Approvals |
|
UL, VDE and CSA |